Knauf Integral

The panel is most commonly used in office spaces for carpet application. Even at a thickness of 30 mm, the EHB panel achieves the fire resistance parameter REI 30, and the load-bearing capacity of 2 kN point, surface load of 10 kN/m2.

Proposed uses:

office premises

Possible floor finishing:

carpet

floor panels

Barlinek board

Technical card

Choose type of load-bearing structure:

TYPE I

Technical data

Panel

Dimensions:

600 x 600 mm

Panel thickness:

30 mm

Top surface:

waterproofing impregnation

Bottom surface:

waterproofing impregnation

System weight:

49,5 kg/m2 (without carpet, for height 250 mm)

Panel weight:

17.2 kg/piece

Panel core:

Integral gypsum with a density of min. 1,500 kg/m3

Load values

Point load in accordance with PN – EN 12825:

2 000 N

Deflection class in accordance with PN-EN 12825:

A

Load-bearing capacity class in accordance with EN 12825:

class 1

Destructive force:

≥ 4 000 N

Safety factor:

≥ 2,0

Fire protection

Reaction to fire according PN – EN 13501 part 1:

A1

Fire resistance according to PN – EN 13501 part 2:

REI 30

TYPE II

Technical data

Panel

Dimensions:

600 x 600 mm

Panel thickness:

30 mm

Top surface:

waterproofing impregnation

Bottom surface:

waterproofing impregnation

System weight:

50.5 kg/m2 (without carpet, for height 250 mm)

Panel weight:

17.2 kg/piece

Panel core:

Integral gypsum with a density of min. 1,500kg/m3

Load values

Point load in accordance with PN – EN 12825:

3 000 N

Deflection class in accordance with PN-EN 12825:

A

Load-bearing capacity class in accordance with EN 12825:

class 1

Destructive force:

≥ 6 000 N

Safety factor:

≥ 2,0

Fire protection

Reaction to fire according PN – EN 13501 part 1:

A1

Fire resistance according to PN – EN 13501 part 2:

REI 30

The panel is dedicated to office spaces with high requirements of load-bearing capacity and fire resistance. The thinnest panel meeting the fire resistance parameter REI 60. The load-bearing capacity for this solution is as much as 4 kN point and 20 kN/m2 or respectively more, depending on the type of load-bearing structure used. The most versatile of all modular panels – all types of finishes can be applied.

Suggested uses:

office premises

public facilities

objects with increased load-bearing capacity and fire resistance requirements

Possible floor finishing:

carpet

floor panels

Barlinek board

gres tiles *

stone *

* prior to designing this type of finish on a raised floor, please contact the technical department

Technical card

Choose type of load-bearing structure:

TYPE I

Technical data

Panel

Dimensions:

600 x 600 mm

Panel thickness:

36 mm

Top surface:

waterproofing impregnation

Bottom surface:

waterproofing impregnation

System weight:

54.4 kg/m2 (without carpet, for height 250 mm)

Panel weight:

19.5 kg/piece

Panel core:

Integral gypsum with a density of min. 1,500kg/m3

Load values

Point load in accordance with PN – EN 12825:

4 000 N

Deflection class in accordance with PN-EN 12825:

A

Load-bearing capacity class in accordance with EN 12825:

class 3

Destructive force:

≥ 8 000 N

Safety factor:

≥ 2,0

Fire protection

Reaction to fire according PN – EN 13501 part 1:

A1

Fire resistance according to PN – EN 13501 part 2:

REI 60

TYPE II

Technical data

Panel

Dimensions:

600 x 600 mm

Panel thickness:

36 mm

Top surface:

waterproofing impregnation

Bottom surface:

waterproofing impregnation

System weight:

54.4 kg/m2 (without carpet, for height 250 mm)

Panel weight:

19.5 kg/piece

Panel core:

Integral gypsum with a density of min. 1,500kg/m3

Load values

Point load in accordance with PN – EN 12825:

5 000 N

Deflection class in accordance with PN-EN 12825:

A

Load-bearing capacity class in accordance with EN 12825:

class 5

Destructive force:

≥ 10 000 N

Safety factor:

≥ 2,0

Fire protection

Reaction to fire according PN-EN 13501 part 1:

A1

Fire resistance according to PN – EN 13501 part 2:

REI 60

TYPE III

Technical data

Panel

Dimensions:

600 x 600 mm

Panel thickness:

36 mm

Top surface:

waterproofing impregnation

Bottom surface:

waterproofing impregnation

System weight:

54.4 kg/m2 (without carpet, for height 250 mm)

Panel weight:

19.5 kg/piece

Panel core:

Integral gypsum with a density of min. 1,500kg/m3

Load values

Point load in accordance with PN – EN 12825:

6 000 N

Deflection class in accordance with PN-EN 12825:

A

Load-bearing capacity class in accordance with EN 12825:

class 6

Destructive force:

≥ 12 000 N

Safety factor:

≥ 2,0

Fire protection

Reaction to fire according PN-EN 13501 part 1:

A1

Fire resistance according to PN – EN 13501 part 2:

REI 60

This is the thinnest floor available on the market. Provides the installation of a fully usable floor with a final floor level of 4cm!

Suggested uses:

office premises

renovated objects

existing facilities adapted for offices

Possible floor finishing:

carpet

floor panels

Barlinek board

Technical card

Choose type of load-bearing structure:

TYPE I

Technical data

Panel

Dimensions:

600 x 600 mm

Panel thickness:

17.4 mm

Top surface:

steel sheet, galvanised, thickness 0.6mm

Bottom surface:

steel sheet, galvanised, thickness 0.6mm

System weight:

37 kg/m2 (without carpet, for height 250 mm)

Panel weight:

12.6 kg/piece

Panel core:

gypsum with a density of min. 1,500kg/m3

Load values

Point load in accordance with PN – EN 12825:

2 000 N

Deflection class in accordance with PN-EN 12825:

A

Load-bearing capacity class in accordance with EN 12825:

class 1

Destructive force:

≥ 4 000 N

Safety factor:

≥ 2.0

Fire protection

Reaction to fire according PN – EN 13501 part 1:

A1

TIM-EX
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.